Managed power distribution unit ND258H1643-4xC19 without plug

TP-PRO-D-12A04B-3P

$ 1,002.11
Managed power strip Control and management of individual sockets 12 C13 sockets, 4 C19 sockets Ping-control function (8 C13 sockets)

Technical Specifications

  • Phase 3
  • PDU type Switched power distribution unit
  • Rated input voltage, V 380
  • Outlet type IEC 320 C13 10A
    IEC 320 C19 16A
  • Outlet quantity 4
    12
  • Max output current, A 16A
  • PDU mounting type Rack mount
  • Product dimensions, mm 482×220×88

Product Info

Part number: TP-PRO-D-12A04B-3P
A rack-mountable Power Distribution Unit (PDU) is a network-managed, autonomous device that allows for the management of 16 outlets through a web interface, SNMP network protocol, or management console. The line of controlled Tesla Power socket blocks is an advanced technical solution for distributing power in telecommunication racks, server rooms, and data centers. Thanks to remote network access and loop connection support, the Tesla Power system is capable of remotely managing equipment at the level of multi-component networks, providing reliable power supply and energy consumption management.

Main features:

  • Precise measurement of total consumed electricity (kWh)
  • Precise measurement of consumed electricity by individual sockets (kWh)
  • Input voltage control
  • Total load current control
  • Individual socket load current control
  • Setting of individual socket current threshold
  • Power factor control
  • Temperature and humidity control (sensors sold separately)
  • Wi-Fi connectivity via USB adapter
  • Individual socket on/off control
  • Setting of sequential on/off delay for individual sockets
  • Ping-control function

The function of measuring consumption for each socket - allows to determine the power consumed through each socket, provides the ability to find out how this power is distributed among the equipment installed in the server rack. These power values allow analyzing the consumption dynamics of each device and planning the distribution of the total power.

The ping-control function - sends ICMP requests to a user-specified IP address, and in the absence of responses, automatically restarts the specified socket.


Technical Specifications

  • Phase 3
  • PDU type Switched power distribution unit
  • Rated input voltage, V 380
  • Outlet type IEC 320 C13 10A
    IEC 320 C19 16A
  • Outlet quantity 4
    12
  • Max output current, A 16A
  • PDU mounting type Rack mount
  • Product dimensions, mm 482×220×88
  • Input plug type IEC60309 16A (3P+N+PE)
  • Input AC frequency, Hz 50/60
  • Cord length, m 2

Managed power distribution...