• Sale

Per port Monitored &amp, Switched PDU Tesla Power PRO series 8 sockets C13, input IEC60309 16A (2P+PE)

TP-PRO-D-08A-1

$ 713.58
$ 935.75
Per port monitored and switched PDU Tesla Power PRO series 8 sockets C13, input IEC60309 16A (2P+PE)

Technical Specifications

  • Operating temperature, °C (1) 0
    50
  • Phase 1
  • PDU type Switched power distribution unit
  • Rated input voltage, V 220
  • Outlet type IEC 320 C13 10A
  • Outlet quantity 8
  • Max output current, A 16A
  • Power cord length, m 2

Product Info

Part number: TP-PRO-D-08A-1

Controlled Power Distribution Unit (PDU) for rack mounting - This autonomous network-controlled device allows you to control eight outlets using a web interface, SNMP network protocol, or a management console.
The line of controlled Tesla Power outlet blocks is an advanced technical solution for power supply distribution in telecommunication racks, server rooms, and data centers (data centers). Thanks to remote network access and support for loop connection, the Tesla Power system can remotely control equipment at the level of multicomponent networks, providing reliable power supply and energy management.

 

Main Features:

  • Accurate measurement of total electricity consumption (kWh)

  • Accurate measurement of electricity consumption by individual outlets (kWh)

  • Input voltage monitoring

  • Monitoring of the total load current

  • Monitoring the load current of individual sockets

  • Setting the threshold current of individual sockets

  • Power factor control

  • Temperature and humidity control (sensors are purchased separately)

  • The ability to connect via Wi-Fi using a USB adapter

  • Turning on/off individual outlets

  • Setting the delay of sequential switching on/off of individual outlets

Consumption measurement function for each outlet - allows you to determine the power consumed through each outlet and makes it possible to find out how this power is distributed among the equipment installed in the server rack.

These power values allow you to analyze the dynamics of consumption by each device and plan the distribution of total power.

The manufacturer can change the appearance and configuration without special notice.

 


Technical Specifications

  • Operating temperature, °C (1) 0
    50
  • Phase 1
  • PDU type Switched power distribution unit
  • Rated input voltage, V 220
  • Outlet type IEC 320 C13 10A
  • Outlet quantity 8
  • Max output current, A 16A
  • Power cord length, m 2
  • PDU mounting type Rack mount
  • Storage temperature, without condensation, °C -10
    60
  • Product dimensions, mm 482.6×216×44.4
  • Input plug type IEC60309 16A (2P+PE)
  • Input AC frequency, Hz 50
  • Net weight, kg 4.6

Per port Monitored &amp,...

$ 935.75 $ 713.58