Uninterruptible power supply SNR-UPS-ONRT-200-25CMX33, on-line, 200kVA, 380-415VAC, 480VDC, non batteries

SNR-UPS-ONRT-200-25CMX33

$ 7,801.31
On-line, Rack-Mounted Modular, 200kVA, 8 slot, 380-415VAC (50/60Hz), 3ph+N+PE, 480VDC (settable even-number batteries from 32 to 44), USB/RS232/DRY CONTACT/SNMP (option)/PARALLEL KIT (option), 7"LCD, IP20, non power modules (chassis only), non batteries

Technical Specifications

  • Type of UPS Modular
  • Phase 3
  • Input voltage 380
  • Battery type Lead-acid (external, ordered separately)
  • Type of UPS (1) Modular online UPS chassis module
  • Without built-in batteries Yes
  • COM port MULTI (RS485
    RS232)
    SNMP slot
  • Percentage of moisture 0 ~ 95% (without condensation)

Product Info

Part number: SNR-UPS-ONRT-200-25CMX33

Chassis of the 200 kVA modular uninterruptible power supply (PF1.0) of the CM series. The chassis accommodates up to 8 modules with a capacity of 25 kVA (25 kVA power modules are purchased separately).

Modular online UPSCM series is designed to protect three-phase power supply systems of servers, data centers, and industrial and medical equipment from power outages, voltage and frequency fluctuations and distortions, pulse, and high-frequency interference.

Modular UPS are suitable for fast-growing small and medium-sized businesses: their architecture allows you to start with a basic configuration with a capacity of 25 kVA and expand it as the business grows to 200 kVA. This design of the UPS allows you to provide redundancy or flexible power build-up.

Modular uninterruptible power supplies of the SM series combine modern three-level technologies of IGBT rectifiers (bipolar transistors with an isolated gate) with the control logic of DSP (digital signal processors). With a high input power factor, low THDi (the total value of the nonlinear distortion coefficient), and high system efficiency, these devices can work with any type of load. The modular design ensures the reliable and stable operation of critical equipment.

 

Each power module is hot-swappable, which makes it easy to increase power and simplifies system maintenance. Independent control of each module eliminates the risks associated with failure due to the failure of one element. In case of failure or disconnection of one module, the system continues to operate and provides an uninterrupted power supply, guaranteeing high reliability and protection.

The main advantages of the CM series UPS:
  • high input power factor (>0.99), low THDi value at the input (<3%);
  • excellent adaptability to linear and nonlinear loads;
  • intelligent protection of the module and system;
  • dual controller DSP for each power module;
  • digital control of all parts, including rectifier, converter, charger, and spark gap;
  • instead of discrete components, integrated IGBT blocks are used in the power module;
  • the presence of a battery cold start module;
  • conformal coating of all printed circuit boards to protect against negative external influences: moisture, pollution, elevated temperatures;
  • built-in switch for input, output, and maintenance connections;
  • large LCD touch screen with comprehensive information;
  • independent battery charging, intelligent battery management system;
  • digital parallelization technology, the current between the modules is very low;
  • full frontal access, cable connection from above and below;
  • each module is equipped with a separate controller, which reduces the risk of failure of one element.

Uninterruptible power supply, can be installed both in the server cabinet and independently

07-0002.jpeg

Technical Specifications

  • Type of UPS Modular
  • Phase 3
  • Input voltage 380
  • Battery type Lead-acid (external, ordered separately)
  • Type of UPS (1) Modular online UPS chassis module
  • Without built-in batteries Yes
  • COM port MULTI (RS485
    RS232)
    SNMP slot
  • Percentage of moisture 0 ~ 95% (without condensation)
  • Number of batteries 40
  • Hour battery rating, A It depends on the capacity of external batteries
  • Expiratory phase 3
  • Output Voltage 380/400/415 V AC
  • Battery voltage 480
  • Input connections Terminal block: three phases, neutral, and ground
  • Backup power supply time at 50% load It depends on the capacity of external batteries
  • Output power factor, RF 1
  • Power, VA 200000
  • Power, W 200000
  • Efficiency in mains operation 95%
  • Intput frequency, Hz 50
  • Output frequency, Hz 50

Uninterruptible power...