On-line, Rack/Tower, 10kVA/10kW, 220-240VAC (50/60Hz), 1ph+N+PE, 192VDC, Terminal, USB/RS232/SNMP, non batteries

Technical Specifications

  • Type of UPS Rackmount
  • Weight, kg (1) 18
  • Operating temperature, °C (1) 0
    40
  • Phase 1
  • Input voltage 176 V~288 V
  • Battery type Lead-acid (external, ordered separately)
  • Type of UPS (1) On-line
  • Without built-in batteries Available

Product Info

Part number: SNR-UPS-ONRT-10000-INTXL

The uninterruptible power supply on-line, 10000 VA Intelligent series, without battery, is made according to the scheme with double conversion (on-line). It provides a stabilized sinusoidal voltage load and is designed for servers, telecommunications, networks, and industrial equipment.

Through the RS232 interface, it is possible to connect to a PC with the UPSilon2000 program installed and configure the UPS status display on the PC monitor. The presence of a slot for the SNMP adapter will allow you to organize monitoring of the UPS through the network.

Power failures can occur at unpredictable times, and the quality of electricity can also change over time. Power supply problems are dangerous for IT equipment, leading to damage to important data, loss of unsaved work sessions, and equipment failure - all this can result in many hours of downtime and expensive repairs.SNR uninterruptible power supplies easily solve these problems, providing high reliability.

Main advantages:
  • extended operating range of the input network, the voltage from 120 to 295 V;
  • synchronization of the UPS output network with the input network in various frequency ranges allows you to provide reliable power to the load;
  • high input power factor;
  • no impact on the input network;
  • maintaining operability at low input voltage;
  • reliable UPS protection functions.

Overall dimensions

photo_2021-06-16_13-44-14.1.jpg

Technical Specifications

  • Type of UPS Rackmount
  • Weight, kg (1) 18
  • Operating temperature, °C (1) 0
    40
  • Phase 1
  • Input voltage 176 V~288 V
  • Battery type Lead-acid (external, ordered separately)
  • Type of UPS (1) On-line
  • Without built-in batteries Available
  • Dimension, mm (1) 86 x 488 x 620
  • COM port EPO
    RS232
    USB
  • Percentage of moisture 0 – 90%
  • Number of batteries 16
  • Hour battery rating, A Depend on capacity of battery
  • Expiratory phase 1
  • Output Voltage 220V ± 10 %
  • Battery voltage 192
  • Input connections Terminal terminal: phase, neutral and ground
  • Output power factor, RF 1
  • Power, VA 10000
  • Power, W 10000
  • Efficiency in mains operation 95
  • Intput frequency, Hz 40-70 Hz
  • Output frequency, Hz 50

Uninterruptible power...