Per port monitored PDU Tesla Power STD series 20 sockets C13, 4 sockets C19, input IEC60309 32A (2P+N)

TP-STD-B-20A04B-32L1

$ 939.74
$ 1,409.00
Per port monitored PDU Tesla Power STD series 20 sockets C13, 4 sockets C19, input IEC60309 32A (2P+N) Network Service: SNMP V1, v2, v3, Logs, HTTP HTTPS , Telnet, NTP, SSL, DHCP, IP V4, TCP,UDP,DNS, SMTP SMTPS, Modbus-RTU, FTP

Technical Specifications

  • Phase 1
  • PDU type Metered power distribution unit
  • Outlet type IEC 320 C13 10A
    IEC 320 C19 16A
  • Outlet quantity 4
    20
  • Max output current, A 32 A
  • Power cord length, m 3
  • PDU mounting type Vertical
  • Input plug type IEC60309 32A (2P+PE)

Product Info

Part number: TP-STD-B-20A04B-32L1

A Power distribution unit (PDU) for vertical mounting (installation in a cabinet from 42U) is an advanced technical solution for power distribution in telecommunication racks, server rooms, and data processing centers (data centers). Thanks to remote network access and support for loop connection, the Tesla Power system can remotely control equipment at the level of multicomponent networks, providing reliable power supply and energy management.

The main advantage of power distribution units of the STD series is the possibility of replacing functional transceivers, which will provide quick and convenient maintenance or repair. Replacement of functional transceivers will allow upgrading BRP from modification A to modification B, C, or D. Also, by replacing the control unit, you can upgrade to a more advanced version of the PDU.

 

Decoding the article:

29-0004.jpeg


Functional features STD

Functions Modification A Modification B Modification C Modification D
Monitoring the energy consumption of each phase
Control of the input voltage of each phase
Monitoring the input current of each phase
Monitoring the power consumption of each phase
Monitoring the power factor of each phase
temperature/humidity control
Monitoring the current of each outlet outlet    
Monitoring the power of each outlet outlet    
Monitoring the power consumption of each outlet outlet    
On/Off of each outlet outlet    
Threshold settings of the input voltage of each phase
Threshold settings of the input current of each phase
Threshold settings of each outlet outlet    
Switching sockets    
Delay in turning on/off the power of a separate outlet    

 

Series comparison PDU (Basic / STD / PRO)

Function Basic STD PRO
Monitoring
Switching  
Electricity measurement
Loop connection
Centralized management
The ability to set a threshold value
Support for the set operating mode after restart  
Hot-swapping the controller module NMC  
Hot-swapping of output modules    
Function Extension port    
Adjustable display direction  
User Management  
Access rights management    
Event and data logs  
Common network and security protocols  
Multiple networks and security protocols    
Possibility to connect temperature and humidity sensors / Logic ports  
Possibility to connect smoke detectors / door openings / water leaks    
English language
Multilingual version    
Managing outlet groups    
Event schedule    
Historical data graph    
Protection against power off during overload    
Loading Mass settings    
Wi-Fi connection    
Supported protocols HTTP, Telnet, SNMP v1/v3, IPv4, SMTP, NTP, HTTP, HTTPS, Telnet, SNMP v1/v2c/v3, IPv4, DHCP, SMTP, SMTPS, SNTP, Modbus RTU, HTTP, HTTPS, Telnet, SNMP v1/v2c/v3, IPv4, DHCP, SMTP, SMTPS, SNTP, Modbus TRU, Radius, syslog, MAC

Technical Specifications

  • Phase 1
  • PDU type Metered power distribution unit
  • Outlet type IEC 320 C13 10A
    IEC 320 C19 16A
  • Outlet quantity 4
    20
  • Max output current, A 32 A
  • Power cord length, m 3
  • PDU mounting type Vertical
  • Input plug type IEC60309 32A (2P+PE)

Per port monitored PDU...

$ 1,409.00 $ 939.74