Uninterruptible power supply SNR-UPS-LID-1500-LED-PRO, Line-Interactive, 1500VA, 220-240VAC, 24VDC (2x7Ah)

SNR-UPS-LID-1500-LED-PRO

$ 115.00
Line-Interactive, Tower, 1500VA/900W, 220-240VAC (50/60Hz), 1ph+N+PE, 24VDC (2x7Ah), USB, RJ-45, 4 x SCHUKO (Outputs), LCD

Technical Specifications

  • Type of UPS Desktop
  • Weight, kg (1) 9,8
  • Operating temperature, °C (1) 0
    40
  • Phase 1
  • Input voltage 162-295 V (AC)
  • Battery type Lead-acid
  • Type of UPS (1) Line-interactive
  • Dimension, mm (1) 220×115×320

Product Info

Part number: SNR-UPS-LID-1500-LED-PRO
Linear-interactive uninterruptible power supplies (UPS) SNR are designed to protect personal computers, workstations, and servers equipped with switch-mode power supplies. Thanks to the built-in battery, the UPS can continue to operate even during a complete power outage, allowing the user to save data and properly shut down the operating system. SNR-UPS-LID uninterruptible power supply sources have a built-in autotransformer. The autotransformer regulates the output voltage when the network voltage changes - in case of excessive increase in the network voltage, the autotransformer lowers the output voltage to an acceptable level, and in case of excessive decrease, it raises it. The autotransformer ensures the specified level of output voltage during fluctuations in the network voltage from the nominal value. A wide range of allowable network voltages reduces the number of cases when the UPS switches to batteries and significantly extends the battery life.

The SNR-UPS-LID UPS is equipped with a “cold start” function, which allows the UPS to be forcibly turned on when there is no mains power.

Device Features

  • AVR increase and decrease for voltage stabilization
  • Auto frequency detection
  • Wide input voltage range
  • Auto diagnostics on startup
  • Automatic restart on power recovery from the grid
  • Automatic network phase tracking to ensure inverter output voltage is in phase with grid voltage, reducing transfer time and voltage spike
  • Intelligent battery management: battery temperature compensation for extended battery life; three-stage charging to reduce recharge time
  • Protection against short circuit, battery overcharge/discharge, overload and overvoltage protection
  • Automatic charging in OFF mode
  • Additional no-load shutdown

Delivery set

User manual.

Technical Specifications

  • Type of UPS Desktop
  • Weight, kg (1) 9,8
  • Operating temperature, °C (1) 0
    40
  • Phase 1
  • Input voltage 162-295 V (AC)
  • Battery type Lead-acid
  • Type of UPS (1) Line-interactive
  • Dimension, mm (1) 220×115×320
  • Maximum number of lines 1
  • Percentage of moisture 20 – 90%
  • Number of batteries 2
  • Hour battery rating, A 8
  • Battery charging current, A 1
  • Expiratory phase 1
  • Output Voltage 220/230/240
  • Type and number of outlet sockets Schuko x 4
  • Battery voltage 24
  • Input connections Built-in power cord with Schuko plug
  • Backup power supply time at 50% load 9 min
  • Output power factor, RF 0,6
  • Power, VA 1500
  • Power, W 900
  • Efficiency in mains operation 70% power mode from the battery
    Power mode from the network 96%
  • Intput frequency, Hz 50/60 Hz ±10% (autodetection)
  • Output frequency, Hz 50/60 Hz ± 1% (autodetection)

Uninterruptible power...