Uninterruptible power supply SNR-UPS-LID-1200-LED-PRO, Line-Interactive, 1200VA, 220-240VAC, 24VDC (2x7Ah)

SNR-UPS-LID-1200-LED-PRO

$ 93.00
Line-Interactive, Tower, 1200VA/720W, 220-240VAC (50/60Hz), 1ph+N+PE, 24VDC (2x7Ah), USB, RJ-45, 4 x SCHUKO (Outputs), LCD

Technical Specifications

  • Type of UPS Desktop
  • Total capacitance, A 7
  • Weight, kg (1) 9,4
  • Operating temperature, °C (1) 0
    40
  • Phase 1
  • Input voltage 162-295 V (AC)
  • Battery type Lead-acid
  • Type of UPS (1) Line-interactive

Product Info

Part number: SNR-UPS-LID-1200-LED-PRO
Linear-interactive uninterruptible power supply sources (UPS) SNR are designed to protect personal computers, workstations, and servers equipped with switching power supplies. Thanks to the built-in battery, the UPS can operate even during a complete power outage, allowing the user to save data and properly shut down the operating system. SNR-UPS-LID uninterruptible power sources have a built-in autotransformer. The autotransformer regulates the output voltage when the network voltage changes - if the network voltage is excessively high, the autotransformer lowers the output voltage to an acceptable level, and if it is excessively low, it raises it. The autotransformer ensures the specified level of output voltage during fluctuations in the network voltage from the nominal. A wide range of allowable network voltages reduces the number of cases where the UPS switches to battery power and significantly extends the service life of the batteries.

The SNR-UPS-LID UPS is equipped with a "cold start" function that allows the UPS to be forcibly turned on when there is no mains power.

Device features

  • AVR increase and decrease for voltage stabilization
  • Auto frequency detection
  • Wide input voltage range
  • Auto diagnosis on startup
  • Automatic restart upon power recovery
  • Automatic grid phase tracking to ensure inverter output voltage is in phase with grid voltage, reducing transfer time and voltage spike
  • Intelligent battery management: battery temperature compensation for extended battery life; three-stage charging to reduce recharge time
  • Protection from short circuit, battery overcharge/discharge, overload, and overvoltage
  • Automatic charging in OFF mode
  • Additional no-load shutdown

Delivery package

User manual

Technical Specifications

  • Type of UPS Desktop
  • Total capacitance, A 7
  • Weight, kg (1) 9,4
  • Operating temperature, °C (1) 0
    40
  • Phase 1
  • Input voltage 162-295 V (AC)
  • Battery type Lead-acid
  • Type of UPS (1) Line-interactive
  • Dimension, mm (1) 220x115x320
  • Percentage of moisture 20 – 90%
  • Number of batteries 2
  • Hour battery rating, A 7
  • Battery charging current, A 1
  • Expiratory phase 1
  • Output Voltage 220/230/240
  • Type and number of outlet sockets Schuko x 4
  • Battery voltage 24
  • Input connections Built-in power cord with Schuko plug
  • Backup power supply time at 50% load 7 min
  • Output power factor, RF 0,6
  • Power, VA 1200
  • Power, W 720
  • Efficiency in mains operation 70% power mode from the battery
    Power mode from the network 96%
  • Intput frequency, Hz 50/60 Hz ±10% (autodetection)
  • Output frequency, Hz 50/60 Hz ± 1% (autodetection)

Uninterruptible power...